Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Braz. j. med. biol. res ; 50(8): e5979, 2017. tab, graf
Article in English | LILACS | ID: biblio-888982

ABSTRACT

As a mechanism compensating for obstructive coronary artery disease, coronary collateral circulation (CCC) has attracted cardiologists for a long time to explore its potential impact. In the present study, Chinese patients suffering from ≥95% coronary stenosis, as diagnosed by angiography, have been investigated for the correlation between CCC and lipoprotein(a) [Lp(a)] levels. A cohort of 654 patients was divided into four categories according to Rentrop grades 0, 1, 2, and 3. Lp(a) levels were divided into model 1, discretized with critical values of 33 and 66%, and model 2, discretized with a cutoff value of 30.0 mg/dL. Furthermore, we evaluated the correlation between CCC and serum Lp(a) levels. The four groups had significantly different Lp(a) levels (25.80±24.72, 18.99±17.83, 15.39±15.80, and 8.40±7.75 mg/dL; P<0.001). In model 1, concerning R0, the risk in the third Lp (a) tertile (OR=3.34, 95%CI=2.32-4.83) was greater than that in the first tertile. In model 2, concerning R0, the risk in Lp(a) >30.0 group (OR=6.77, 95%CI=4.44-10.4) was greater than that of Lp(a) <30.0 mg/dL. The worst condition of CCC can be predicted independently by Lp(a) levels. In addition to clinical usage, Lp(a) levels can also be utilized as biological markers.


Subject(s)
Humans , Male , Female , Middle Aged , Collateral Circulation/physiology , Coronary Artery Disease/blood , Coronary Artery Disease/diagnostic imaging , Coronary Circulation/physiology , Coronary Occlusion/blood , Lipoprotein(a)/blood , Biomarkers/blood , Cohort Studies , Coronary Angiography , Coronary Artery Disease/physiopathology , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/physiopathology , Predictive Value of Tests , Risk Factors
2.
Rev. bras. cir. cardiovasc ; 29(4): 505-512, Oct-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-741730

ABSTRACT

Objective: To perform a comparative assessment of two surgical techniques that are used creating an acute myocardial infarc by occluding the left anterior descending coronary artery in order to generate rats with a left ventricular ejection fraction of less than 40%. Methods: The study was completely randomized and comprised 89 halothane-anaesthetised rats, which were divided into three groups. The control group (SHAM) comprised fourteen rats, whose left anterior descending coronary artery was not occluded. Group 1 (G1): comprised by 35 endotracheally intubated and mechanically ventilated rats, whose left anterior descending coronary artery was occluded. Group 2 (G2): comprised 40 rats being manually ventilated using a nasal respirator whose left anterior descending coronary artery was occluded. Other differences between the two techniques include the method of performing the thoracotomy and removing the pericardium in order to expose the heart, and the use of different methods and suture types for closing the thorax. Seven days after surgery, the cardiac function of all surviving rats was determined by echocardiography. Results: No rats SHAM group had progressed to death or had left ventricular ejection fraction less than 40%. Nine of the 16 surviving G1 rats (56.3%) and six of the 20 surviving G2 rats (30%) had a left ventricular ejection fraction of less than 40%. Conclusion: The results indicate a tendency of the technique used in G1 to be better than in G2. This improvement is probably due to the greater duration of the open thorax, which reduces the pressure over time from the surgeon, allowing occlusion of left anterior descending coronary artery with higher accuracy. .


Objetivo: Realizar uma avaliação comparativa de duas técnicas cirúrgicas que são usadas para criar um infarto agudo do miocárdio pela oclusão da artéria coronária descendente anterior esquerda, a fim de gerar ratos com uma fração de ejeção ventricular esquerda inferior a 40%. Métodos: O estudo foi completamente randomizado e composto por 89 ratos anestesiados com halotano, que foram divididos dentro de três grupos. O grupo controle (SHAM) composto por 14 ratos, cuja artéria coronária descendente anterior esquerda não foi ocluída. Grupo 1 (G1): composto por 35 ratos intubados endotraquealmente e ventilados mecanicamente, cuja artéria coronária descendente anterior esquerda foi ocluída. Grupo 2 (G2): constituído por 40 ratos sendo ventilados manualmente utilizando um respirador nasal, cuja artéria coronária descendente anterior esquerda foi ocluída. Outras diferenças entre as duas técnicas incluem o método de realizar a toracotomia e remover o pericárdio, a fim de expor o coração, e o uso de diferentes métodos e tipos de sutura para fechar o tórax. Sete dias após a cirurgia, a função cardíaca de todos os ratos sobreviventes foi determinada por ecocardiografia. Resultados: Nenhum rato do grupo SHAM foi a óbito ou teve fração de ejeção ventricular esquerda menor que 40%. Nove dos 16 ratos sobreviventes do G1 (56,3%) e seis dos 20 ratos sobreviventes do G2 (30%) tiveram uma fração de ejeção ventricular esquerda inferior a 40%. Conclusão: Os resultados indicam uma tendência da técnica utilizada no G1 ser melhor do que a do G2. Esta melhora deve-se provavelmente à maior duração do tórax aberto, o que reduz a pressão de tempo sobre o cirurgião, permitindo uma oclusão da artéria coronária descendente anterior esquerda com maior acurácia. .


Subject(s)
Animals , Male , Coronary Occlusion/etiology , Coronary Vessels/surgery , Disease Models, Animal , Myocardial Infarction/etiology , Myocardial Infarction/surgery , Ventricular Dysfunction, Left/etiology , Coronary Occlusion/physiopathology , Coronary Vessels/physiopathology , Echocardiography , Heart/physiopathology , Myocardial Infarction/physiopathology , Myocardial Infarction , Random Allocation , Rats, Wistar , Reproducibility of Results , Stroke Volume/physiology , Time Factors , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left
3.
Rev. bras. cardiol. invasiva ; 21(4): 311-318, out.-dez. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-703681

ABSTRACT

INTRODUÇÃO: Há poucos dados na literatura que avaliam a obstrução coronária após implante transcateter de válvula aórtica (TAVI, do inglês transcatheter aortic valve implantation) para o tratamento de disfunção de bioprótese aórtica (valve-in-valve - ViV). O presente estudo avaliou, por meio de revisão sistemática da literatura, as características clínicas, o manejo e os desfechos clínicos de pacientes com obstrução coronária após TAVI-ViV. MÉTODOS: Estudos publicados entre 2002 e 2013 avaliando a obstrução coronária como complicação de TAVI-ViV foram identificados por meio de busca eletrônica sistemática. Foram avaliados dados basais sobre as características clínicas e do procedimento, manejo da complicação e desfechos clínicos. RESULTADOS: Foram identificadas, no total, quatro publicações descrevendo sete pacientes. A maioria dos pacientes era do sexo feminino (71%), sendo a média de idade de 82 ± 5 anos, com STS-PROM de 9,4 ± 2,6%. As médias da altura do tronco da artéria coronária esquerda (TCE) e o diâmetro médio da raiz aórtica foram de 8,8 ± 1,5 mm e 28,0 ± 5,0 mm, respectivamente. A maioria dos pacientes apresentava biopróteses com suporte e folhetos montados externamente, ou eram próteses sem suporte (stentless) e o TCE foi envolvido em todos os casos. A intervenção coronária percutânea (ICP) foi tentada em todos os pacientes, tendo sucesso em quatro deles (57%). A mortalidade intra-hospitalar foi 42,9% (três casos), todos após ICP sem sucesso. CONCLUSÕES: A obstrução coronária após TAVI-ViV ocorreu mais frequentemente em mulheres com bioprótese com suporte e folheto montado externamente ou com bioprótese sem suporte. O TCE foi envolvido em todos os casos e a ICP foi realizada com sucesso em 60% deles. Esforços contínuos poderão auxiliar na detecção dos fatores associados a essa complicação, no intuito de se implementarem medidas apropriadas para sua prevenção.


BACKGROUND: Very few data exist on coronary obstruction following transcatheter aortic valve implantation (TAVI) for degenerative bioprosthetic valves (valve-in-valve - ViV). The present study evaluated, through a systematic review of the literature, the clinical characteristics, management and clinical outcomes of patients with coronary obstruction after ViV-TAVI. METHODS: Studies published between 2002 and 2013 evaluating coronary obstruction as a complication of ViV-TAVI were identified using a systematic electronic search. Data on the clinical and procedural characteristics, management of the complication, and clinical outcomes were analyzed. RESULTS: A total of four publications describing seven patients were identified. Most patients (71%) were women, with mean age of 82 ± 5 years, and STS-PROM score of 9.4 ± 2.6%. Mean left coronary artery (LCA) ostium height and aortic root width were 8.8 ± 1.5 mm and 28.0 ± 5.0 mm, respectively. Most patients had stented bioprosthetic valves with externally mounted leaflets or stentless aortic bioprosthesis, and the LCA was involved in all patients. Percutaneous coronary intervention (PCI) was attempted in all patients and was successful in four (57%). In-hospital mortality was 42.9% (three cases), all of them after failed PCI. CONCLUSIONS: Coronary obstruction following ViV-TAVI occurred more frequently in women with stented bioprosthetic valves with externally mounted leaflets or with stentless bioprosthesis. The LCA was involved in all cases and PCI was successful in 60% of them. Continued efforts may help identify the factors associated with this complication so that appropriate prevention measures may be implemented.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Coronary Occlusion/physiopathology , Aortic Valve/physiopathology , Echocardiography , Percutaneous Coronary Intervention/adverse effects , Risk Factors , Stents
4.
Rev. bras. cardiol. invasiva ; 21(1): 67-72, jan.-mar. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-674491

ABSTRACT

INTRODUÇÃO: A oclusão percutânea do canal arterial é um método seguro, eficaz e facilmente reproduzível. O canal arterial do adulto pode apresentar alterações degenerativas, que aumentam o risco da cirurgia e favorecem o procedimento percutâneo. Descrevemos a experiência de um centro único com a oclusão percutânea do canal arterial em adultos e destacamos aspectos técnicos particulares desse procedimento. MÉTODOS: Revisamos os registros de todos os pacientes > 20 anos de idade submetidos a oclusão do canal arterial entre março de 2001 e dezembro de 2012. Os casos foram selecionados por ecocardiografia transtorácica. RESULTADOS: Analisamos 33 pacientes, a maioria do sexo feminino (72,7%), com médias de idade de 30,9 ± 12,8 anos e de peso de 63,9 ± 12,4 kg. Somente 3 pacientes tinham sintomas e 2 pacientes apresentaram defeitos associados, tratados no mesmo procedimento. Os implantes foram possíveis em todos os casos. Foram utilizadas 1 mola Flipper, 19 próteses AmplatzerTM Duct Occluder tipo I, 3 próteses AmplatzerTM Duct Occluder tipo II, 8 próteses CeraTM PDA Occluder e 2 próteses para comunicação interventricular muscular. O uso de balões medidores foi necessário em 5 casos. O seguimento médio foi de 46,1 ± 42,9 meses e foi obtido em 84,9% dos pacientes. Dois casos apresentaram shunt residual imediatamente após o procedimento. Não ocorreram complicações maiores ou óbitos. CONCLUSÕES: A oclusão percutânea dos canais dos adultos com os dispositivos empregados pode ser realizada com segurança e eficácia.


BACKGROUND: Percutaneous closure of patent ductus arteriosus is a safe, effective and easily reproducible method. Adult patent ductus arteriosus may present degenerative changes that increase surgical risk and favor percutaneous closure. We report a single center experience with percutaneous closure of patent ductus arteriosus in adults and highlight specific technical aspects of this procedure. METHODS: The records of patients > 20 years of age submitted to patent ductus arteriosus closure between March 2001 and December 2012 were evaluated. Cases were selected by transthoracic echocardiography. RESULTS: We analyzed 33 patients, most of them females (72.7%), with mean age of 30.9 ± 12.8 years and weight of 63.9 ± 12.4 kg. Only 3 patients had symptoms and 2 had associated congenital defects, treated in the same procedure. Implants were possible in all cases. One Flipper Coil, 19 AmplatzerTM Duct Occluders type I, 3 AmplatzerTM Duct Occluders type II, 8 CeraTM PDA Occluders and 2 Muscular VSD devices were used. Sizing balloons were used in 5 cases. Mean follow-up was 46.1 ± 42.9 months and was obtained in 84.9% of patients. Two cases presented residual shunts immediately after the procedure. There were no major complications or deaths. CONCLUSIONS: Percutaneous closure of adult patent ductus arteriosus may be performed safely and effectively with the devices used in this study.


Subject(s)
Humans , Male , Female , Adult , Adult , Coronary Occlusion/physiopathology , Ductus Arteriosus, Patent/physiopathology , Angiography , Echocardiography , Heart Defects, Congenital , Prostheses and Implants , Retrospective Studies
5.
Rev. bras. cardiol. invasiva ; 21(3): 270-275, 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-690660

ABSTRACT

INTRODUÇÃO: A oclusão da artéria radial (OAR) é uma complicação clinicamente silenciosa do cateterismo transradial, mas pode predispor à isquemia da mão. Fatores associados a essa complicação conhecidos são o calibre dos introdutores e cateteres, a dose de heparina utilizada, o número de reutilizações da artéria radial e o tipo de curativo compressivo aplicado. O objetivo deste estudo foi avaliar se existe associação entre a utilização de introdutores vasculares hidrofílicos reprocessados e a OAR. MÉTODOS: Pacientes submetidos a cateterismo transradial foram randomizados para introdutores novos (Grupo I - GI) ou reprocessados (Grupo II - GII). A presença de OAR foi avaliada em 24 horas (precoce) e 30 dias (tardia), por meio do teste de Barbeau reverso. RESULTADOS: Foram alocados 228 pacientes no GI (n = 100) e no GII (n = 128). A idade foi de 60,1 ± 10,6 anos vs. 59,4 ± 10,9 anos (P = 0,64), 49% vs. 35,2% (P = 0,03) eram do sexo feminino e 25% vs. 27,3% (P = 0,70) eram diabéticos. Observaram-se incidências totais de OAR precoce de 10,5% e de 9,1% para OAR tardia. Dez pacientes do GI (10%) apresentaram OAR precoce, comparados a 14 (10,9%) do GII (χ² = 0,05; RR = 1,09; P = 0,82). Na avaliação de 30 dias, foi encontrada OAR em 6 pacientes do GI (7,5%) comparados a 11 pacientes (10,4%) do GII (χ² = 0,45; RR = 1,38; P = 0,50). CONCLUSÕES: Na casuística estudada, não foi encontrada associação entre a reutilização de introdutores vasculares e a OAR precoce e tardia em pacientes submetidos a cateterismo cardíaco.


BACKGROUND: Radial artery occlusion (RAO) is a clinically silent complication of transradial catheterization but may predispose to hand ischemia. Factors associated with this complication are the diameter of catheters and sheaths, the dose of heparin, repeated transradial procedures and the type of compressive dressing applied. The objective of this study was to evaluate if there is an association between reused hydrophilic vascular introducers and RAO. METHODS: Patients undergoing transradial catheterization were randomized to receive brand new introducers (Group I - GI) or reprocessed introducers (Group II - GII). The presence of RAO was evaluated at 24 hours (early) and day 30 (late) with the reverse Barbeau test. RESULTS: Two hundred and twenty-eight patients were assigned to GI (n = 100) and GII (n = 128). Mean age was 60.1 ± 10.6 years vs. 59.4 ± 10.9 years (P = 0.64), 49% vs. 35.2% (P = 0.03) were female and 25% vs. 27.3% (P = 0.70) were diabetic. An total early RAO incidence of 10.5% and a late RAO incidence of 9.1% were observed. Ten GI patients (10%) had early RAO when compared to 14 (19.9%) in GII (χ² = 0.05; HR: 1.09; P = 0.82). On the 30-day follow-up RAO was observed in 6 GI patients (7.5%) when compared to 11 GII patients (10.4%) (χ² = 0.45; HR = 1.38; P = 0.50). CONCLUSIONS: In our study no association was found between reused vascular introducers and early and late RAO in patients undergoing cardiac catheterization.


Subject(s)
Humans , Male , Female , Middle Aged , Radial Artery/physiopathology , Cardiac Catheterization/adverse effects , Coronary Occlusion/complications , Coronary Occlusion/physiopathology , Equipment Reuse/economics , Data Analysis , Heparin/therapeutic use , Percutaneous Coronary Intervention/methods , Prospective Studies
6.
In. Timerman, Sergio; Dallan, Luís Augusto Palma; Geovanini, Glaucylara reis. Síndromes coronárias agudas e emergências cardiovasculares / Acute coronary syndromes and cardiovascular emergencies. São Paulo, Atheneu, 2013. p.265-281.
Monography in Portuguese | LILACS | ID: lil-719904
SELECTION OF CITATIONS
SEARCH DETAIL